(Specifier Note: The purpose of this guide
specification is to assist the specifier in correctly
specifying gypsum sheathing products and installation. The
specifier needs to edit the guide specifications
to fit the needs of specific projects. Contact
a CertainTeed Product Representative to assist in making
the appropriate product selections. Throughout
the guide specification, there are Specifier notes
to assist in the editing of the file. The term
Architect is used throughout these guide specifications,
as a guide and may be edited to read “Design
Professional”,” Engineer”, “Owner” or
other appropriate designation as required for specific
project.
References have been made within the text of the
specification to MasterFormat 2004 Section numbers
and titles, specifier need to coordinate this numbers
and titles with sections included for the specific
project. Brackets [ ]; “AND/OR”;
and “OR” have been used to indicate when
a selection is required.)
SECTION 06 16 43
GYPSUM SHEATHING
PART 1 - GENERAL
1.1 SECTION INCLUDES:
- Treated Core Gypsum Sheathing
- Exterior Gypsum Soffit
Board
- Glass-Reinforced Gypsum Sheathing
- Accessories and
Trim
1.2 REFERENCES
A. ASTM International (ASTM)
-
ASTM C 514 - Standard Specifications
for Nails for the Application of Gypsum Board.
- ASTM
C 920 - Standard Specification for Elastomeric
Joint Sealants
- ASTM C 954 - Standard Specification
for Steel Drill Screws for the Application
of Gypsum Panel Products or Metal Plaster
Bases to Steel Studs From 0.033 in.
to 0.112 in. in Thickness
- ASTM C 1002
- Standard Specification for Steel
Self-Piercing Tapping Screws for
the Application of Gypsum Panel Products
or Metal Plaster Bases to Wood Studs
or Steel Studs
- ASTM C 1047 - Standard
Specification for Accessories For Gypsum Wallboard
and Gypsum Veneer Base
- ASTM C 1177-
Standard Specification for Glass Mat Gypsum Substrate
for Use as Sheathing
- ASTM
C 1280 - Standard Specification
for Application of Gypsum Sheathing
- ASTM C 1396
- Standard Specification for Gypsum Board
- ASTM
E 84 - Standard Test Method for Surface Burning
Characteristics of Building Materials
B. Gypsum Association
- GA - 253 – Application of
Gypsum Sheathing
- GA - 254 – Fire-Resistant Gypsum
Sheathing
- GA - 600 - Fire Resistant Design
Systems; Gypsum Association
C. Underwriters Laboratories Inc
- UL - Fire
Resistance Directory
1.3 SUBMITTALS
A. Refer to Section [01 33
00 Submittal Procedures] [insert
section number and title].
B. Product Data: Submit manufacturer current
technical literature for each component.
C. Samples:
- Board: Submit sample of each panel
product specified, [6 inches square] [insert size].
- Trim: Submit sample of each type
of trim specified, [12 inches long] [insert size].
D. Quality Assurance Submittals
(Specifier Note: DELETE
Design Data, Test Report submittal requirements
when propriety specification is used and can
be held. MAINTAIN Design Data, Test Report
submittal requirement when other products may
be submitted as substitution.)
- Design Data, Test Reports: Provide manufacturer
test reports indicating product compliance with
indicated requirements.
- Manufacturer Instructions: Provide manufacturer’s
written installation instructions.
E. Closeout Submittals
- Refer to Section [01 78
00 Closeout Submittals] [insert section
number and title].
1.4 QUALITY ASSURANCE
- Qualifications: Installer shall have experience
with installation of gypsum sheathing under similar
conditions.
1.5 DELIVERY, STORAGE AND HANDLING
- Deliver materials in manufacturer’s
original packages, indicating manufacturer and
product name.
- Store gypsum in accordance with manufacturer
recommendations.
PART 2 - PRODUCTS
(Specifier Note: Product Information
is proprietary to CertainTeed America Inc. products.)
2.1 MANUFACTURER
- Basis of Design: CertainTeed America
Inc.; 5301 West Cypress Street, Suite 300, Tampa,
FL 33607; 1-866-4 CertainTeed USA (1-866-427-2872); www.bpb-na.com
- Equivalent Design: Manufacturer
with products of equivalent design may include,
but are not limited to:
- National Gypsum Company
- USG Corporation
2.2 GYPSUM
SHEATHING
- Treated Core Gypsum Sheathing
- Standard Treated Core Sheathing:
Water-repellent sheathing for exterior
applications. Complying
with ASTM C1396.
- Basis of Design: ProRoc® Sheathing
Treated Core, manufactured by CertainTeed America
Inc.
- Thickness: 1/2 inch
- Width: [24 inches] [48 inches]
[24 inches or 48 inches]
- Length: [8 feet] [9 feet] [10
feet] [12 feet] [Use longest length
available to avoid joints]
- Edges: [Square] [Tongue and Groove]
- Fire Rated Treated Core Sheathing:
Water-repellent sheathing with a specially
formulated core for use in fire-resistive
designs. Complying
with ASTM C 1396.
- Basis of Design: ProRoc® Sheathing
Treated Core Type X, manufactured by CertainTeed
America Inc.
- Thickness: 5/8 inch
- Width: 48 inches
- Length: [8 feet] [9 feet] [10
feet] [12 feet] [Use longest length
available to avoid joints]
- Edges: Square
- Exterior Gypsum Soffit Board
- Regular Exterior Soffit Board: Gypsum
core soffit panel with sag resistant core.
Complying with ASTM C 1396.
- Basis of Design: ProRoc® Exterior
Soffit Board, manufactured by CertainTeed America
Inc.
- Thickness: 1/2 inch.
- Width: 48 inches.
- Length: [8 feet] [12 feet] [Use
longest length available to avoid
joints]
- Edges: Tapered
- Fire Rated Exterior Soffit Board: Gypsum
core soffit panel with enhanced fire and
sag resistant core for use in fire
resistive designs. Complying with ASTM
C 1396, Type X.
- Basis of Design: ProRoc® Exterior
Soffit Board Type X, manufactured by
CertainTeed America Inc.
- Thickness: 5/8 inch.
- Width: 48 inches.
- Length: [8 feet] [12 feet] [Use
longest length available to avoid
joints]
- Edges: Tapered
- Glass-Reinforced Gypsum Sheathing
- Glass-Reinforced Gypsum Sheathing: Weather
resistant sheathing with CertainTeed Enhanced Glass Reinforced
Gypsum Technology. Complying with ASTM
C 1177.
- Basis of Design: GlasRoc® Sheathing,
manufactured by CertainTeed America Inc.
- Thickness: 1/2 inch
- Width: 48 inches
- Length: [8 feet] [9 feet] [Use longest
length available to avoid joints]
- Edges: Square
- Flame Spread/Smoke Developed: 0/0
when tested in accordance with ASTM E
84.
- Fire Rated Glass-Reinforced Gypsum
Sheathing: Weather resistant sheathing with
CertainTeed Enhanced Glass Reinforced Gypsum
Technology and fire resistive core. Complying
with ASTM C 1177.
- Basis of Design: GlasRoc® Sheathing
Type X, manufactured by CertainTeed America Inc.
- Thickness: 5/8 inch
- Width: 48 inches
- Length: [8 feet] [12 feet] [Use
longest length available to avoid
joints]
- Edges: Square
- Flame Spread/Smoke Developed: 0/0
when tested in accordance with ASTM E
84.
2.3 ACCESSORIES
- Trim: Complying with
ASTM C 1047.
- Cornerbead
- LC-Bead
- Control Joint
- Fasteners:
- Screws: [ASTM
C 954] [ASTM C 1002] as recommended by panel manufacturer.
- Nails: ASTM C 514 with heads, lengths,
configurations, and finish as recommended
by panel manufacturer.
- Joint Treatment
- Tape: Self-adhering glass fiber tape,
minimum 2 inches wide, 10 by 10 mesh,
as recommended by sheathing and sealant
manufacturer.
- Sealant
(Specifier Note: The use
of a separate water-resistive barrier may permit
joints and fasteners to be untreated depending
on local code requirements. Sealants
may be specified in this section or may be specified
elsewhere in Division 07. EDIT paragraphs
below dependent upon location of sealant specification.)
- Refer to Section [07
92 00 Joint Sealants] [insert
section number and title].
OR
- Provide sealant that complies with
ASTM C 920, silicone sealant to maintain watertight
conditions and as recommended by tape and sheathing
manufacturer.
PART 3 - EXECUTION
3.1 SHEATHING INSTALLATION
- Glass-Reinforced Gypsum
Sheathing: Install
in accordance with [GA-253]
[ASTM C 1280] and
sheathing manufacturer recommendations.
- Fire
Rated Glass-Reinforced Gypsum Sheathing:
Install in accordance with [GA-600]
[UL design] and sheathing manufacturer recommendations.
3.2 PROTECTION
- Protect installed products
from damage during remainder of the construction
period.
- Remove and replace panels that are
damaged.
END OF SECTION
|