Exterior Wall Systems - Exterior Archways, Exterior Concave & Convex Surfaces

CLICK IMAGE FOR ENLARGED DETAIL

09253

Refer to finish system manufacturer for glass mesh reinforcement requirements.

Recommended Lengthwise Bending Radii
Sheathing Board Thickness
Tested - Bent Lengthwise Radii
12.7mm (1/2") GlasRoc Sheathing
1800mm - (6')
15.9mm (5/8") GlasRoc Sheathing Type X
2400mm - (8')

GlasRoc® Sheathing is engineered for use in curved exterior gypsum board applications. There is no need to score or moisten the board to bend it. To prevent flat areas in the curved surface, framing should be positioned at a maximum spacing of 150 mm (6").

Consult the Gypsum Association document GA-226 for framing recommendations.


Application to Archways
GlasRoc® Sheathing can be installed in an archway or on a concave or convex surface by applying pressure onto the board to fit the radius and then holding it firmly in place while fastening it to the framing members. To best seat the product in tight radius applications, temporarily install a stop at one end of the framed radius to serve as a restraint support. Install the product with coated side out with one of the width ends placed flush against the temporary stop and secure with fasteners, one framing member at a time. Repeat until the product has been secured to all framing members. Fasteners should be spaced no greater than 200 mm (8") apart.

Referenced Standards
ASTM C 954: Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.33 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
ASTM C 1002: Standard Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases
ASTM C 1280: Standard Specification for Application of Gypsum Sheathing
ASTM C 1177: Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing
ASTM C 1397: Practice for Application of Class PB Exterior Insulation and Finish Systems
CAN/ULC-S102 / ASTM E 84: Test Method for Surface Burning Characteristics of Building Materials
ASTM E 96: Test Methods for Water Vapour Transmission of Materials

PRODUCT INFORMATION:
Product Benefits
Literature
High Performance Sheathing
Warranty
Case Studies
TECHNICAL ISSUES :
Physical
Properties
Architectural Specifications
Installation - Fastening Patterns
Installation - Framing & Joint Treaments
Technical Downloads

FREQUENTLY ASKED QUESTIONS

APPLICATIONS:
Cavity Wall
Exterior Cladding
EIFS
Conventional Stucco
Exterior Archways, Convex, Concave Surfaces
Fire Rated
Exterior Soffits
Portions of this site require these fine products:  
Copyright ©01/07 CertainTeed Corp. Privacy | Terms of Use | Corporate Information | Trade Shows | Press Room | Site Map